Simple vacuum extraction primarily relies on air being drawn towards an extraction opening. Active non-contact cleaning also creates controlled airflow close to the substrate to mobilize contamination before it is extracted. In a Weducon system, fan-generated cleaning airflow, ionization, and extraction work together within the cleaner. The extraction airflow exceeds the supplied clean airflow, helping […]
What drives the ongoing development of Weducon web cleaning technology?
Production processes, materials, and requirements continue to change. Higher recycled content can change contamination loads, while lean production increases the focus on stable output with less waste, energy use, maintenance, and unnecessary production stops. Noise exposure, dust containment, and efficient system integration are also increasingly important. Weducon therefore continues to develop airflow efficiency, filtration, controls, […]
Is non-contact web cleaning effective?
Yes. Properly engineered and correctly applied non-contact web cleaning can effectively remove loose and electrostatically influenced dust, fibres, and particles without touching the substrate. “Non-contact” only describes the absence of mechanical contact; it does not by itself determine cleaning performance. The result depends on how contamination is mobilized, captured, and extracted, and on how well […]
How does Weducon reduce energy use and maintenance requirements?
Operational efficiency depends on more than the cleaner head alone. To reduce energy use and maintenance, Weducon combines aerodynamic pressure and vacuum chambers with frequency-controlled airflow and a matching self-cleaning filter/fan unit. The airflow is adjusted to the required cleaning performance, avoiding unnecessary resistance and energy loss, while the extracted contamination is separated from the […]
Does the boundary layer make non-contact web cleaning ineffective?
No. A boundary layer is a near-surface airflow created as a moving web entrains surrounding air. It is not a physical barrier that prevents non-contact cleaning. It does, however, mean that airflow close to the web must be deliberately controlled. In a Weducon cleaner, the incoming web-generated airflow is guided into the cleaning zone before […]
Does the HEM-70 reduce noise levels in production environments?
Yes. The system operates at up to 25% lower noise levels compared to conventional systems, contributing to a cleaner and more comfortable working environment in narrow web production facilities.
How energy-efficient is the HEM-70 compared to conventional systems?
The HEM-70 typically operates with up to 30% lower energy consumption than conventional non-contact cleaning systems. Its optimized airflow design and efficient AFC filter/fan unit provide stable cleaning performance with reduced operational load.
How is the HEM-70 integrated into existing narrow web lines?
The system can be mounted using base or cantilever brackets and utilizes existing mounting locations. Electrical integration requires PLC integration and frequency-controlled fan operation. Installation is straightforward using standard industrial connectors.
Does the HEM-70 require consumables or HEPA cassettes?
No. The system uses long-life filter cartridges with sub-micron filtration and antistatic coating. No disposable HEPA cassettes are required, and the filter medium has a life expectancy of at least 60 months under normal operating conditions.
Why are the ionizers positioned inside the cleaner instead of in front of it?
When ionization is placed in front of the cleaner, loose particles are released before the extraction system can capture them. This creates the risk of particles ending up in the air or on the floor. With ionization in the center of the cleaner, the released particles are immediately removed. That’s why the HEM-70 integrates 24V […]
Is the HEM-70 suitable for explosion-sensitive environments?
The COL270B-AL filter cartridges are ATEX certified and grounded throughout. The antistatic aluminium coating ensures high electrical conductivity (Rd < 10³ Ohm), effectively dissipating electrostatic charges and enhancing safety in explosion-sensitive production environments. The pneumatic cleaning valves are ATEX certified, and when a placement in an ATEX zone is needed, the motor specifications can be […]
How does the self-cleaning AFC filter system prevent performance loss over time?
The AFC filter/fan unit uses reverse-jet pulse cleaning to continuously regenerate the filter cartridges. Heavy contaminants are pre-separated and collected in a dust tray before reaching the filter media, preventing overload and ensuring constant airflow performance over long operating periods.
How fine are the particles removed by the HEM-70 system?
The HEM-70 achieves 99.9% filtration efficiency for particles in the 0.2–2 μm range. The AFC filter unit uses sub-micron filtration media (dust class M), ensuring minimal particle escape and preventing recontamination of the substrate.
Does substrate origin matter for effective cleaning?
No. Effective cleaning at the press infeed is independent of the substrate’s origin. Even when sheets or webs are delivered pre-processed, contamination can still be introduced during transport and handling. Cleaning directly before printing addresses this risk.
Do Weducon systems require major press modifications?
In most cases, no. Integration depends on the press model, available space and safety requirements. Retrofit installations are commonly designed to fit into the existing line, with mounting and controls adapted to the press, so operator workflows remain largely unchanged.
Does dust extraction replace substrate cleaning?
No. Dust extraction and substrate cleaning address different issues. Extraction reduces airborne particles in the press environment, while substrate cleaning removes contamination from the substrate surface itself. In practice, extraction helps keep the press area cleaner, while substrate cleaning directly affects print quality. Many plants use both to achieve stable and predictable print quality.
Why is cleaning at the press infeed critical in printing processes?
Because the press infeed is the last controlled point before the substrate enters the printing process. Dust and fibres can be introduced at various stages, including transport, storage and handling, regardless of how or where the substrate was produced. Cleaning directly at the press infeed helps prevent contamination from entering the press, reducing print defects, […]
What is the difference between web cleaning and sheet cleaning in printing?
Web cleaning is used for continuous substrates in web-fed processes such as offset, where the material runs uninterrupted through the press. Sheet cleaning is applied to individual sheets in sheet-fed presses, such as flexo and digital presses, where each sheet is cleaned before entering the press. The choice depends on substrate format, line speed and […]
How are Weducon web cleaning systems typically applied in paper and board manufacturing lines?
In paper and cardboard production, Weducon web cleaning systems are integrated at points where fibres, dust, and microparticles are generated, such as after slitting or cutting, or before winding and stacking. The system’s configuration and positioning are determined by the web width, line speed, material properties, and contamination characteristics, ensuring effective dust extraction without disrupting […]
How does static charge interact with fibre release and dust adhesion in paper production?
Static charge increases particle adhesion by attracting fibres and dust to the web surface and edges, as illustrated in our knowledge article on static control. This interaction not only amplifies contamination build-up but also reduces the effectiveness of passive removal methods, making controlled ionisation an important factor in effective web cleaning.
Why is edge contamination in paper webs harder to control than surface contamination?
Contamination at the edges is more difficult to control because fibers and cutting residues are generated there and are less affected by surface airflow patterns. Because the open edges are no longer covered by coating, fillers and binders break loose, releasing the long fibers as well. This debris tends to accumulate, migrate further down the […]
How do fibre type, coating, and cutting method influence contamination behaviour on paper webs?
Fibre length, stiffness and bonding influence how easily fibres detach during processing, while coatings affect surface adhesion and electrostatic behaviour. Cutting and trimming methods further determine particle size and release intensity, which directly impacts whether contamination remains airborne, adheres to the web, or migrates to edges.
Where in the paper production line does contamination become structurally embedded in the web or roll?
Contamination becomes structurally embedded when fibres and dust are included upstream of winding, slitting, or stacking. At these stages, particles are compressed into the web or trapped between layers in rolls or stacks, making downstream removal ineffective and increasing the risk of surface dents, print defects and handling issues.
Which contamination mechanisms are most critical in high-speed paper and board production?
In high-speed paper and board lines, contamination is primarily driven by fibre release during formation, trimming and cutting, particularly in grades with higher recycled fibre content, where shorter fibres and fines are more easily released. Combined with airflow and static effects around the moving web, these particles are readily transported downstream and embedded into rolls […]
Does a Weducon cleaning system eliminate static charge?
Weducon actively neutralizes static charge within the controlled cleaning zone. This reduces the electrostatic component of particle adhesion at the point where the cleaning airflow can immediately mobilize and extract contamination. This does not mean that the substrate will remain permanently free of static charge after leaving the cleaner. Subsequent friction, contact with rollers, material […]
Can a Weducon retrofit be installed without affecting existing equipment warranties?
Weducon retrofit installations are engineered to minimise or avoid modifications to existing production equipment. Wherever possible, we use existing mounting points, independent support structures and separate controls. Weducon’s Automatic Impulse Generator (AIG), for example, allows the cleaning system to operate independently of the machine PLC when direct control integration is not preferred. If modifications or […]
How long does installation take, and does it require production downtime?
A typical Weducon retrofit installation can often be completed within 18–22 hours and planned around a scheduled maintenance stop or weekend. Weducon prepares the installation while production is still running. This includes engineering, measurements, prefabrication and coordination of the mechanical, electrical and pneumatic work. Once the line is stopped, the installation generally proceeds in stages: […]
When is web or sheet cleaning necessary?
Web or sheet cleaning is necessary when dust, fibres and loose particles interfere with product quality, production efficiency, equipment performance or working conditions. Typical indications include contamination-related defects during printing, coating or laminating; disruption of sensitive processes such as digital printing; and unacceptable contamination risks in food, pharmaceutical or other hygiene-critical production environments. Cleaning should […]
Where should a web or sheet cleaner be installed?
The best position to install a web or sheet cleaner depends on the source of the contamination and the objective of the cleaning process. As a general principle, contamination should be removed as close as practical to either: the point where it is generated the critical process step it could disrupt the point before different […]
What does effective web cleaning improve in production?
Effective web cleaning reduces the amount of dust, fibres and loose particles entering critical downstream processes. Depending on the application, this can contribute to: fewer contamination-related defects and rejects more stable product quality and printing performance longer intervals between wash-ups and manual cleaning stops reduced maintenance requirements improved production uptime and throughput less material waste […]










